User's Manual

545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
168 © 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute.
COMMAND DESCRIPTION PARAMETERS RANGE
*P{,?}{,xxx}{,OFF}
Configures 545C for pulse probe mode. If no
parameters are entered, transmit single pulse
probe. Enter transmit single pulse probe. Enter
P,? to display current pulse probe mode settings.
Enter P,xxx to send a single periodic probe once
every “xxx” seconds. Enter P,OFF to turn off
periodic pulse mode (you can still transmit single
pulses with P).
? = current settings
xxx = periodic pulse period
(in seconds)
OFF = turn off periodic pulse
mode
P77 The P77 command must be used to place the
Julian date into position one, and Hour/Minute
into position two. With this setup, the MCC 545C
will strip off the first two sensor values and place
the date and time derived from these values into
the standard MCC 550B report.