COMMAND DESCRIPTION PARAMETERS RANGE
MESSAGE
{,p{,dest1…destn}}
Enter a message with text editor. Message
priority and destination are optional parameters.
After entering message, press [ESC] to queue for
transmission. If you do not enter a destination
ID, the MCC-545C automatically sends your
message to its default destination (set with the
DESTINATION command). If you want to use
source rounting, enter 0 for the destination.
p = priority
dest1...destn =
destination(s)
name = node name
nnnn = Station ID
Master = 1 – 245
Remote = 256 – 4095
A – Z, 0 – 9
A – Z, 0 – 9
1 – 4095
MM Print current value of RF signal on Receiver in
dBm.
MODE Print operating mode information.
*MODULATION,degree,
encoding
Set the transmit modulation and data encoding.
IMPORTANT
MCC-545C modulation must be the same as
other units in the network.
degree =
90 or 30
encoding =
MAN(Manchester),
DIFF(Dfferential)