User's Manual

545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
© 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute. 161
COMMAND DESCRIPTION PARAMETERS RANGE
If device – Remote: Normal
operation
†*ID{,nnn,mmm{,mode}
{,INIT}}
NOTE
Remote and Master IDs are
kept in CPM and mode is kept
in BBU RAM.
Set 545C’s assigned Master Station ID to number
“nnn”. When no parameters are given, current
ID is displayed. When system is already
initialized, you must enter the INIT parameter to
change ID. INIT gives “OK” to save configuration
and reboot unit with new ID. ID changes are
automatically saved with the entire
configuration in CPM. “mode” parameter (if
used) specifies initial connectivity with specified
Master. PREF means Remote considers
connectivity established. AUTO means no
connectivity established. MULTI means Remote
can connect to multiple Master Stations. FIXED
(Default) means connect only with specified
Master.
NOTE
If command does not change the ID or Master
Station, the SAVE and reboot are not performed.
nnn = Remote ID
mmm = Master ID
mode mode =
PREF, AUTO,
MULTI, or FIXED
256 – 4095
1 – 245
†ID,mode Change “mode” as discussed above without
affecting ID; no reboot performed.
mode = PREF, AUTO,