User's Manual

545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
156 © 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute.
COMMAND DESCRIPTION PARAMETERS RANGE
GENERIC,Port,SENSOR,AUTO
In AUTO mode, sensor values are delimited by
blanks or commas and there may be several per
line.
GENERIC GENERIC, P,
SENSOR, AUTO, Line Number,
Start
If the line number is given, data can start on
other than the 1
st
line.
GENERIC , P, SENSOR, LINE,
Line Number, Start, End
if the start parameter is given, data can begin in
a column other than the 1
st
column.
GENERIC,Port,POLL,POLLSTRI
NG,Interval
The polling feature can be used for data loggers
that do not print a data report unsolicited, but
require some command string to be sent to
request the next report. The poll string can be
any printable ASCII characters up to 20 bytes in
length. The INTERVAL parameter is given in
decimal and is the number of seconds between
outputting the poll string.
GENERIC,Port,REPORT,OFF