User's Manual

545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
154 © 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute.
COMMAND DESCRIPTION PARAMETERS RANGE
GENERIC,Port,TYPE,{AUTO,LI
NE,OFF}
This command selects whether the report is in a
single line format or multiple line format. AUTO
specifies single line with free-format, and LINE
specifies the multiple line format. The OFF
option is provided to turn off a previously set-up
port.
GENERIC,Port,GROUP,AUTO The AUTO group numbering will start at group
number 1 and increment by 1 for each 16 sensor
values.
GENERIC,Port,GROUP,LINE,1s
tGrpNo,START,END
The LINE option allows the group number to be
within the data at the given line number and
between the given start and end column
numbers.
GENERIC,Port,GROUP,FIXED,
GrpNo
The FIXED option will use the Line Number
parameter as the first group number then
increment by 1 for each 16 sensor values.
GENERIC,Port,GROUP,SCALE,{
FLOAT,INT}
The SCALE option will scale sensor values by the
factor given. (Default scale is “1”.)