COMMAND DESCRIPTION PARAMETERS RANGE
EVENT,{DIOHIDIOLOW},BIT,S
ETTLE,HOLDOFF,ACTION
Define an event that looks for a discrete input
line to go to a high/low level.
DIOHI = Scan discrete input
signal for high condition.
DIOLOW= Scan discrete
input signal for low
condition.
Bit-name= Name of discrete
input signal to be scanned
for high level. (single or
multiple inputs)
Settle= Number of clock
ticks for the input signal to
settle at the high level
before clearing an event
Holdoff= Number of clock
ticks for the analog input
signal to settle at the low
level to be armed for
detecting the next event.
Action= MCC-545C action to
be taken when the event is
declared. See actions below.