COMMAND DESCRIPTION PARAMETERS RANGE
DQERXQ,nnnn:sss Delete specified message from the receive
queue
nnnn=Station ID
Master = 1 – 245
Remote = 256 – 4095
sss = msg serial number
1 – 4095
1 – 245
DQETXQ,nnnn:sss Delete specified message from the transmit
queue
nnnn=Station ID
Master = 1 – 245
Remote = 256 – 4095
sss = msg serial number
1 – 4095
1 – 245
*DUTY CYCLE {,percent}
Set/display transmitter duty cycle (default is
10%). Duty cycle increases in increments of 5%.
percent = 1 – 100 1 – 100
EVENT
Show Event Table. For details, please refer to
Section 4.6 and Appendix D.
EVENT,DEL,ALL
Delete Event Table.
EVENT,DEL,n
Delete Event Number 'n'.
EVENT,RESET,ACTION
Define an action to be taken at power-up/reset.