User's Manual
545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
138 © 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute.
COMMAND DESCRIPTION PARAMETERS RANGE
DIRECT, p, CONNECT
RESPONSE, response-text-
string
Defines a text string to be output by the MCC-
545C to the external equipment to confirm a
connection has been established.
DIRECT, p, PACKET TIMEOUT,
decimal-imeout-ticks
Defines the timeout period in 1/16 second clock
ticks that marks the end of a packet. After each
character of the packet is received the timer is
reset. After the last character has been received
and the timeout passed, the characters received
will be placed in a message and queued for
transmission.
DIRECT, p, PACKET
TERMINATOR, OFF
Disable packet termination using a specified
character code.