User's Manual

545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
132 © 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute.
COMMAND DESCRIPTION PARAMETERS RANGE
†CR10X,GROUP,source
Specify source of data report group assignment.
source =
545C – 545C assigns group
numbers; CR10X internal
group number matches data
array
CR10X – CR10X assigns
group numbers; 545C gets
group number from first
sensor
†CR10X,INTERVAL,n Acquisition scan interval in seconds. OFF disables
acquisition scan
n = seconds 0 – 32767
CR10X,MAXQ,nnn Set maximum number of reports to queue for
each scan of the CR10X
nnn = number of reports 1 – 200
CR10X,ORDER,order
Specify order of final storage data (currently only
FIFO is available).
order =
FIFO – first in, first out
LIFO – last in, last out