User's Manual

545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
120 © 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute.
Bit Name I/O; Voltage Range Definition Description
C1 – C8
32-bit Counters can
be used both as an
input and as an
output. Counters can
range from 0 to
16,777,216 counts.
0 or n
Counter registers
.
These can be set to a value,
cleared to zero, incremented or decremented. A 0
decrements to 16,777,216. A 16,777,216 increments
to 0.
A1-A24
32-bit Accumulators
can be used both as
an input and as an
output. Value can
range from 0 to +/-
16,777,216
0 or n
General purpose accumulators
.
These are used for
computational or temporary storage of numerical
values.
Each of the bit-names in the above table can be used in Event and Action
definitions. The DIOHI/DIOLOW events can use DTR, RTS, IN1-4, GPS, NET,
T1-T8, C1-C8, A1-A24 as inputs. The Action parameter can use BIT0-BIT15,
CTS, RING, MCLK, MDIR, MSET, RO1-R02, T1-T8, C1-C8, A1-A24 as outputs.
Examples:
EVENT,DIOHI,IN1,16,16,SET,RO1 Waits for input line 1 to go high for 1
second, then sets RO1 to NC.
EVENT,DIOLOW,DTR,16,16,SET,T1,160 Waits for DTR to go high for 1
second, then starts timer-1 at 160 counts (10 seconds).
EVENT,DIOLOW,T1,1,1,TXT,1 Waits for timer-1 to go to
zero, then sends a text message indicating that DTR timed-out.
5.6.10 ADC Channel Names
Channel
Name
Definition Description
FPWR
Forward RF
power
RF power going out of the MCC
-
545C transmitter.
RPWR
Reverse RF
power
RF power being reflected back to the MCC
-
545C
transmitter.
LBAT
Battery level
Voltage level of the MCC
-
545C battery.
DETRF
Detected RF
Current
MCC
-
545C receiver detected RF level.
TEMP
Internal
temperature
Internal temperature of the MCC
-
545C enclosure.
TXC
Transmit Count
Total number of transmissions
ACK
Acknowledge
Count
Total number of acknowledgements