User's Manual
545C Operations Manual
02/10/2012 Prerelease DCN 00001789-A
© 2012 Meteorcomm LLC. All Rights Reserved. Proprietary and Confidential. Do Not Distribute. 95
10 Net atm. radiation 2120.4 W/sqm
11 Rainfall 204.6 mm
From the above report one can see that the date is on line 1 in columns 12-
19, and is in year-month-day format. The time is also on line 1 in columns
21-28. Sensor data then starts on line 2 and repeats on subsequent lines in
columns 25-30. The label fields are ignored.
Group Number: GENERIC, P, GROUP, AUTO
GENERIC, P, GROUP, LINE, line number, start, end
GENERIC, P, GROUP, FIXED, line number
The AUTO group numbering will start at group number 1 and increment by
1 for each 16 sensor values. The LINE option allows the group number to be
within the data at the given line number and between the given start and
end column numbers. The FIXED option will use the “line number”
parameter as the first group number then increment by 1 for each 16
sensor values.
Date: GENERIC, P, DATE, AUTO
GENERIC, P, DATE, LINE, line number, start, end,{FORMAT}
The AUTO date option will use the MCC-545C internal Date. The LINE
option allows the date to be within the data at the given line number and
between the given start and end column numbers. The FORMAT is optional,
and shows a “template” of the date format. It can be “mm/dd/yy”,
“yy/mm/dd”, “mmddyy”, “yymmdd”. If the format is not given it will
default to the “mm/dd/yy” format.
Time: GENERIC, P, TIME, AUTO
GENERIC, P, TIME, LINE, line number, start, end,{FORMAT}
The AUTO time option will use the MCC-545C internal time. The LINE
option allows the time to be within the data at the given line number and
between the given start and end column numbers. The FORMAT is optional,
and shows a “template” of the time format. It can be “hh:mm:ss”,
“hh:mm”, “hhmmss”, “hhmm”. If the format is not given it will default to
the “hh:mm:ss” format. The MCC-545C SDATA reports are only time-tagged
with month-day-hour-minute. Year and seconds are not transmitted.