Instruction Manual

OPERATIONS 4-46
MCC-545C PACKET DATA RADIO
12/2000
MCC-545C COMMANDS
COMMAND DESCRIPTION PARAMETERS RANGE
†*SNP{pname,value}
NOTE
Some network parameters
are only for use in Master
Operation mode
(RDOWN, CONNP,
TEXTL, FLOODP, INF,
RELAY).
NOTE
TTL, TTR, NUP,
NDOWN, RDOWN,
OTL, HTO, TEXTL,
CONNP, ETEAP,
FLOODP, RELAY and
INF are kept in EEPROM;
DATAP and MBHOP are
kept in BBU RAM.
Set network parameters. See range column for values
entered for each parameter.
pname – TTL
time-to-live
TTR time-to-
retransmit
N UP neighbor
up
N DOWN
neighbor down
R DOWN
Remote down
OTL outstanding
text limit
CONNP
connectivity msg.
precedence
ETEAP End-to-
End ACK
precedence
HTO history file
timeout
TEXTL text size
in segments
FLOODP partial
flooding prec.
level
INF infinity hop
quantity
DATAP priority
of data reports
created by MCC-
545C
0 – 2550 min.
(truncated to 10 min.
bndry)
default = 120
0 – 255 min.
default = 20
1 – 255 acq.
default = 20
1 – 255 min.
default = 20
0 – 32767
default = 1440
1 – 255
default = 20
0 – 9, A – Z
default = 1
0 – 9, A – Z
default = 0
1 – 255 min.
default = 120
5 – 255
default = 32
A – I
default = A
2 = 255 hop
default = 8
A – Z
default = Y
1 – 99
default = 1
ON, OFF