Instruction Manual

OPERATIONS 4-43
MCC-545C PACKET DATA RADIO
12/2000
MCC-545C COMMANDS
COMMAND DESCRIPTION PARAMETERS RANGE
SCALE{,parameter,value
}
Display set A/D scaling factors for the unit. Factors
depend on type of receiver and power supply used in the
MCC-545C.
parameter =
BAT – battery
voltage
DETRF
detected RF
TXPWR
transmit
power
value = scale
factor
†SCHED{,basis,hh:mm:ss
{,OFFSET,hh:mm:ss},
command string}
IMPORTANT
SCHED ignores the
MESSAGE command. Up
to 50 events can be
scheduled.
Schedule execution of the specified command string. If
timeframe basis = INTERVAL, the command string will
be executed whenever the specified time interval elapses
during the day. If timeframe basis = TIME, the
command string will be executed at the specified time.
The OFFSET option allows specification of an offset
from the timeframe basis.
basis = TIME or
INTERVAL
hh - hours
mm - minutes
ss - seconds
0 – 23
0 – 59
0 – 59
SCHED,DEL,nn Delete specified schedule item number. If nn = ALL, the
entire schedule will be cleared.
nn = schedule
item number
1 – 50
SDATA,g,c,time stamp,
value...
Enter an MCC-550C data report directly from the serial
I/O port. Up to 16 values may be entered. Use the
LINK command to route the data.
g = group number
c = sensor count
time stamp =
mmdddhhmn
value = ASCII
hex sensor value
1 – 4
1 – 16
mm 1 – 12
ddd 1 –365
hh 0 – 23
mn 0 – 59
0 – FFFF