Instruction Manual
OPERATIONS 4-36
MCC-545C PACKET DATA RADIO
12/2000
MCC-545C COMMANDS
COMMAND DESCRIPTION PARAMETERS RANGE
†OPEN PORT Resume activity on specified closed port. You can enter
more than one port name to open, using commas to
separate the names on the same line.
CAUTION
The OPEN/CLOSE PORT commands directly affect
MCC-545C network activity and message flow. Do
NOT use these commands.
function = user
interface function
MNT, POS, MSG,
ALT, DTA, C&S
*P{,?}{,xxx}{,OFF} Configures MCC-545C for pulse probe mode. If no
parameters are entered, transmit single pulse probe.
Enter transmit single pulse probe. Enter P,? to display
current pulse probe mode settings. Enter P,xxx to send a
single periodic probe once every “xxx” seconds. Enter
P,OFF to turn off periodic pulse mode (you can still
transmit single pulses with P).
? = current
settings
xxx = periodic
pulse period (in
seconds)
OFF = turn off
periodic pulse
mode
P77
The P77 command must be used to place the Julian date
into position one, and Hour/Minute into position two.
With this setup, the MCC MCC-545C will strip off the
first two sensor values and place the date and time
derived from these values into the standard MCC 550B
report.