Instruction Manual
OPERATIONS 4-32
MCC-545C PACKET DATA RADIO
12/2000
MCC-545C COMMANDS
COMMAND DESCRIPTION PARAMETERS RANGE
If device – Remote:
Normal operation
†*ID{,nnn,mmm{,mode}
{,INIT}}
NOTE
Remote and Master IDs are
kept in EEPROM and
mode is kept in BBU
RAM.
Set MCC-545C’s assigned Master Station ID to number
“nnn”. When no parameters are given, current ID is
displayed. When system is already initialized, you must
enter the INIT parameter to change ID. INIT gives
“OK” to save configuration and reboot unit with new ID.
ID changes are automatically saved with the entire
configuration in EEPROM. “mode” parameter (if used)
specifies initial connectivity with specified Master.
PREF means Remote considers connectivity established.
AUTO means no connectivity established. FIXED
(Default) means connect only with specified Master.
NOTE
If command does not change the ID or Master Station,
the SAVE and reboot are not performed.
nnn = Remote ID
mmm = Master
ID
mode = PREF,
AUTO or
FIXED
256 – 4095
1 – 245
†ID,mode Change " mode" as discussed above without affecting ID;
no reboot performed.
mode = PREF,
AUTO or FIXED
If device = Master:
*ID{,nnn{,INIT}}
Set MCC-545C’s assigned Master Station ID to number
“nnn”. When no parameters are given, current ID is
displayed. When system is already initialized, you must
enter the INIT parameter to change ID. INIT gives
“OK” to save configuration and reboot unit with new ID.
ID changes are automatically saved with the entire
configuration in EEPROM.
CAUTION
If you enter INIT, you will lose all current message
information.
nnn = assigned
Master ID
1 – 245