OPERATIONS 4-30
MCC-545C PACKET DATA RADIO
12/2000
MCC-545C COMMANDS
COMMAND DESCRIPTION PARAMETERS RANGE
*HALF DUPLEX{,n}
NOTE
Duplex state is kept in
EEPROM and probe
interval is kept in BBU
RAM.
Set Master Station to half-duplex mode and specify
number of milliseconds between idle probes. If no
parameter specified, last setting is used (default = 30).
n = milliseconds
between idle
probes
30 – 30,000
HELP{,command} Display help information on specified command. If no
parameter entered, all commands are sequentially
displayed in alphabetical order.
command = valid
MCC-545C
command
*HOLD
Select message hold mode.
HORN,function{,open,
close,on,off,duration}
Defines horn timing setup function = TEST,
FLOOD,
STAGE 2,
STAGE3, ALL
CLEAR
open = valve
opening time
close = valve
closing time
on = on time
off = off time
duration = overall
duration for
on/off cycle
All times in seconds
1 – 15
1 – 15
1 – 3600
1 – 3600
1 - 3600