Instruction Manual

OPERATIONS 4-23
MCC-545C PACKET DATA RADIO
12/2000
MCC-545C COMMANDS
COMMAND DESCRIPTION PARAMETERS RANGE
†CLOSE PORT,function
{,function,…}
Close specified MCC-545C port from operation. You
can enter more than one port name to close, using
commas to separate the names on the same line.
CAUTION
The OPEN/CLOSE PORT commands directly affect
MCC-545C network activity and message flow. Do
NOT use these commands unless directed to do so.
function = user
interface function
MNT, POS, MSG,
ALT, DTA, C&S
CLS
Print current values, then clear link statistics (see STAT).
COMPRESSION{,actio
n}
Enable/disable data compression on outbound
messages/data reports. Intermediate nodes pass on the
information in compressed form. The destination
decompresses the information.
action =
ON – enable
OFF – disable
CONFIG
Show current configuration parameters report.
NOTE
Configuration in EEPROM may differ unless the SAVE
command is used after configuration changes are made.
CONFIGURATION
List major Master Station configuration settings.
†CONNECT,{nnn…} Limits Master-to-Master connectivity for lab and field
network configuration
nnn = Master
Station
OFF = no
limitation
1 – 245
CORPAT
Without parameters, display report of available
correlation patterns and indicate usage.