User Manual

4
Channel LED
· Green --- On / Ready
· Red ------ Open connection: tip, connector
· Off ------- Channel not selected or channel is in Auto Off
(cycle the power switch to reset)
AC Power LED
· Green --- Power On
· Red ------ Ground Fault
· Off ------- Power Off
Auto-Sleep and Auto Off Functions
To prolong tip life, MFR systems with a soldering hand-piece (MFR-H1-SC2, MFR-H2-
ST2) include an Auto-Sleep Workstand (WS1). When the hand-piece is placed into the
workstand, the Auto-Sleep Workstand immediately reduces power to the hand-piece.
All MFR systems have an Auto Off Function. The Auto Off Function will be engaged
when the hand-piece has been idle in the sleep stand for a period of two hours. The
channel LED indicator light will go from green to off. The Auto Off Function can be
reset by cycling the power switch.
LED Indications and Meaning
System Specifications
Ambient Operating Temperature 10- 40°C
Maximum Enclosure Temperature 55°C
Input Line Voltage 100- 240 VAC, grounded circuit
Input Line Frequency 50/60 Hz
Power Consumption
MFR-1100 70 Watts max.
MFR-2200 130 Watts max. (With both channels on)
Output Power Max. 60 Watts max. Per channel at 22°C ambient
temperature
Output Frequency 450--480 KHz
Power Cord 3-Wire 183cm (18/3) SJT
Dimensions w x d x h
MFR-1100 90mm (3.5), 297mm (8), 142 mm (5.6)
MFR-2200 122mm (4.8), 200mm (8), 152.5mm (6)
Certification / Marking cTUVus, CE
Tip-to-Ground Potential <2mV
Tip-to-Ground Resistance <2 ohms
Idle Temperature Stability ± 1.1°C in still air
Hand-piece Cable Length L=122cm (48), burn proof, ESD safe
Hand-piece Connector 8-pin circular DIN
Workstand Dimensions w x d x h 100 mm (4) x 200 mm (8) x 100 mm (4) max
MFR-PS1100 MFR-PS2200