Datasheet
www.okinternational.com
7 of 11
Selecting Exhaust Arms, Nozzles and Cabinets
The selection of the fume capture device should be guided by your application and work habits. Very often the
user has a certain preference for a certain nozzle design. Review the “Application” column, nozzle styles and
airflow ratings of the table below and select an exhaust arm / nozzle which suits best your needs.
All exhaust arms are made of ESD material and are supplied with a mounting bracket and two C-clamps. The
universal design allows for mounting the arms to bench tops, rails or shelves.
Exhaust cabinets are recommended for the capture of volatile gases and strong odors.
Exhaust Arm
Arm
Diameter
mm / inch
Length
cm / inch
Nozzle Sizes and Styles
Estimated
Airflow
m
3
/h (cfm)
Application
BVX-Arm
50 mm /
2”
71cm / 28”
Round: 40mm / 1.75” diameter
75 m
3
/h /
45 cfm
Point and small area
extraction for
- Soldering
- Gluing / bonding
- Laser marking fumes
BVX-ArmL
50 mm /
2”
122cm / 48”
Omniflex Arm
EA1122
63 mm /
2.5”
60cm / 24”
Rectangular: 150 x 88mm /
6” x 3.5”
140 m
3
/h /
85 cfm
Area extraction for
- Soldering
- Gluing / bonding
- Solder pots
- solvent vapors
Omniflex Arm
EA1126
63 mm /
2.5”
60cm / 24”
Large rectangular hood:
350 x 212mm / 14” x 8.5”
140 m
3
/h /
85 cfm
Large area extraction for:
- Soldering of large boards
- Large solder pots
- Gluing / bonding
- solvent vapors
Omniflex Arm
EA1124
63 mm /
2.5”
60cm / 24”
Oval: 30mm / 1.25” wide
50 m
3
/h /
30 cfm
Point extraction for:
- soldering under
microscope
- laser marking fumes
Exhaust
Cabinet
EC1500
100mm
(4”) port
N/A
760Wx510
Dx560mm
(H)
(30”Wx20”D
x22”H)
250 m
3
/h /
150 cfm
- volatile gases
- toxic gases
- odors
Optional Accessories for Omniflex arms are
AC1101 Damper / shut-off valve
AC1102 Extension 300mm (1’) long
Omniflex Arm Features:
A “ball / socket” design which allows to made the arm shorter or
longer by just simply removing or adding Omniflex components.