Datasheet

www.okinternational.com
2 of 11
Which System Should I Buy?
Volume Extraction
Models with
Pre / HEPA / Gas filtration
Applications: soldering / solder pots /
small ovens / lasers
Models with
Pre / Gas filtration
Applications: vapors from solvents,
conformal coating, adhesives, etc.
Single User
BVX-100 Series
75m
3
/h (45cfm) on plenum or
BVX arm
BVX-101 - includes 1 BVX-Arm
BVX-101S - plenum only
BVX-103 - includes 1 BVX-Arm
BVX-103S - plenum only
Single User
BVX-200 Series
with 1 Omniflex arm
140m
3
/h (85cfm) per Omniflex arm
BVX-201and 1 Omniflex Arm
connected via flexible hose
BVX-203 and 1 Omniflex Arm
connected via flexible hose
Two Users less than 1 m (40”) apart
BVX-200 Series
75m
3
/h (45cfm) per BVX arm
BVX-201-Kit- includes 2 long
BVX arms
BVX-203 and 2 long BVX arms
Two Users on separate tables
BVX-200 Series
75m
3
/h (45cfm) per
arm
BVX-201 with two arm kits BVX-
Arm-K1. Kit includes 1.8m (6’)
long hoses
Longer hoses available.
BVX-203 with two arm kits BVX-
Arm-K1. Kit includes 1.8m (6’)
long hoses
Longer hoses available.
Multi Users up to 8
MFX-2200 Series
- with BVX arms for
moderate fumes, 75m
3
/h (45cfm) per arm
- with Omniflex arms for heavy fumes
140m
3
/h (85cfm) per arm
MFX-2206C-A (analog control)
MFX-2206C-D (digital control)
Up to 4 stations with Omniflex arms
Up to 8 stations for BVX arms or
Omniflex EA1124. Requires Y-piece.
MFX-2206G-A (analog control)
MFX-2206G-D (digital control)
Up to 2 Omniflex arms or 2 exhaust
cabinets
Up to 4 Omniflex arms with optimal
lid AC2202
4” exhaust port connection:
exhaust cabinets, small ovens or
lasers
MFX-2200 Series
MFX-2206C-A (analog control)
MFX-2206C-D (digital control)
Requires optional lid AC2204 for
100mm (4”) diameter ports.
MFX-2206G-A (analog control)
MFX-2206G-D (digital control)
Standard lid has two 100mm (4”)
ports
Tip Extraction up to 8 users
BTX-208
Not Applicable