Fume Extraction Planning Guide Which System Should I Buy? ............................................... 2 BVX-100 Configurations ....................................................... 3 BVX-200 Configurations ....................................................... 4 MFX-2200 Configurations..................................................... 5 Selecting Control of MFX-2200 ............................................ 6 Selecting Exhaust Arms, Nozzles and Cabinets ................... 7 Tip Extraction ....
Which System Should I Buy? Volume Extraction Single User BVX-100 Series Models with Pre / HEPA / Gas filtration Applications: soldering / solder pots / small ovens / lasers Models with Pre / Gas filtration Applications: vapors from solvents, conformal coating, adhesives, etc.
BVX-100 Configurations On bench with plenum: BVX-101-S Filter Unit, single user, plenum only On bench with BVX-Arm: BVX-101 Filter Unit, single user, with exhaust arm On shelf with Inverted Adapter and BVX-Arm: BVX-101-S Filter Unit, single user, plenum only BVX-IADT Inverted arm adapter, ESD safe BVX-Arm Flexible arm, ESD, 710mm (28”) long Alternative arm: BVX-ArmL Flexible arm, ESD, 1220mm (48”) long A) With Under Bench Bracket: BVX-101-S Filter Unit, single user, plenum only BVX-BCK Under bench bracke
BVX-200 Configurations 760 mm (30”) long arm, 50 mm (2”) in diameter 1.5 m (59”) long arm, 50 mm (2”) in diameter BVX-Arm-K1 Fasten to table with clip BVX-201-Kit: Exhaust arms are directly inserted into ports of filter unit. The arm can be fastened with a clip to the table for stability. BVX-201-Kit Filter Unit with 2 flexible arms BVX-200 with flexible hoses and BVX arms: Use flexible hoses for greater spacing between arms.
MFX-2200 Configurations Pre / HEPA / Gas with Exhaust Arms AC2025 Y-piece with clamps MFX-2206C-A Filter Unit P/H/G Analog MFX-2206C-D Filter Unit P/H/G Digital Up to 8 BVX-Arms per unit BVX-ARM-K2: includes arm with mounting bracket and C-clamps Up to 8 Omniflex arms # EA1124 EA1124 Arm with tapered nozzle including bracket and C-clamps Standard top cover has 4 air inlets 63mm (2.5”) dia. Up to 4 Omniflex arms per unit EA1122 Omniflex w/ rect. nozzle EA1126 Omniflex w/ large hood CH0251 Hose 63mm (2.
Selecting Control of MFX-2200 2 1 Models with Analog Control ON / OFF switch (1) Gauge (2) indicates filter condition of particulate filter Models with Digital Control (New digital board available from December 2005) Displays all critical system parameters Alerts when critical conditions exist Allows quick-view of programmed settings Reset of factory default settings possible Programmable auto-shut-down (ASD) except for temperature 1 2 9 3 8 4 7 5 6 Display Functions Descriptio
Selecting Exhaust Arms, Nozzles and Cabinets The selection of the fume capture device should be guided by your application and work habits. Very often the user has a certain preference for a certain nozzle design. Review the “Application” column, nozzle styles and airflow ratings of the table below and select an exhaust arm / nozzle which suits best your needs. All exhaust arms are made of ESD material and are supplied with a mounting bracket and two C-clamps.
Tip Extraction The new BTX-208 is an electric driven tip extraction unit which can provide fume extraction for up to 8 stations. The filter unit itself and the connection accessories are designed for easy planning and installation.
Individual parts of Connection Kits: Part Number Description CH0121 Flexible hose Ø 35mm x 2.5m (8’) long CH0122 Flexible hose Ø 35mm x 5m (16’) long CH0123 Flexible hose Ø 35mm x 7.5m (25’) long AC-TX001-4 Couplings with two glands 5.
Commonly Asked Questions Are fumes hazardous to my health? Yes, most industrial fumes contain more dangerous chemicals than cigarette fumes. Solder fumes, for example can cause minor respiratory symptoms but also occupational asthma, and skin allergies. Lead-free solders often contain fluxes made up even of harsher chemicals. Check the safety data sheets which identify these health hazards.
Do I need to use a pre-filter? A pre-filter is highly recommended as it prolongs the life of the more expensive HEPA filter. Will your unit filter the chemicals from the supplied list? If the chemical is in a particulate form, the HEPA filter will remove it efficiently to safe levels. If the chemical is a gas, we recommend checking the chemical against a list of substances which have been tested for absorption by activated carbon. This list provides an absorption efficiency guide for many common chemicals.