<Function 167> GS ( k pL pH cn fn n (fn=67)
Code:
ASCII
GS ( k pL pH cn fn n
Hex
1D 28 6B 03 00 31 43 n
Decimal
29 40 107 3 0 49 67 n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=49
fn=67
1<=n<8
Default:
n = 3
Description:
This command sets the size of the QR Code module to n dots.
Remarks:
The setting of this command affects the processing of <Function 181> and <Function 182>.
Since the QR CODE module is square, n = module width = module height.
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences: