<Function 48> BS ^ P fn (fn=0,48)
Code :
ASCII
BS ^ P fn m t
Hex
08 5E 50 fn m t
Decimal
08 94 84 fn m t
Range:
fn=0,48, 0 ≤ m ≤ 1
5 ≤ t ≤ 255
Default:
m = 1, t = 20
Description :
■ Set the power saving mode and time to change the sataus of printer.
Remarks :
■ The m=0 : power saving mode disable.
■ The m=1 : power saving mode enable.
■
The power saving set time is [t x 1s] and the default time is 20 sec.
• If n is smaller than 5 the power saving time is set to defaut [20 x 1s].
Differences:
None