User`s manual
Rev. 1.00
- 15 -
Metapace L-2
3-4-5 Narrow Ribbon Installation
When using ribbons of widths of 110mm or
lower, install in a centered position on the
holder ribbon.
3-4-6 Ribbon Removal
1) Use a knife or other sharp-edged object to cut the ribbon.
(Take care not to injure hands)
2) Open the ribbon assembly and remove the ribbon and core by pushing from left to right.
3) Detach the ribbon holder from the ribbon and core.
3-4-7 Ribbon Sensor Activation
To activate the ribbon sensor, check to see if the dip switch is properly set. (Refer to dip
switch table) If the ribbon sensor is inactive, detection of low ribbon levels and/or
disconnected ribbon is not possible.
※ CAUTION
1. When replacing a ribbon, keep affixed the core of the fully used ribbon to the ribbon
coiling portion on the other side and do not discard as its use is required.
2. As the ribbon holder is required for continuous use, make sure not to misplace it.
Cutting