Technical Specifications

HBL T8 H IG H- BAY I NDUS TR IA L LU MINAI RE
Ballast Type
T8 Systems
(4)
Blank=(1) or (2) 120/277V T8 Instant
Start Electronic, 1.15 BF
PS=(1) or (2) 120/277V T8 Electronic
Program Rapid Start, 1.15 BF
(7)
Ordering Information Sample Number: HBL-632-N-UNV-EB82-UPL-U Includes V Hangers for rapid installation
(6)
Quick Ship Ordering Information Sample Number: HBL432-MP-UPL-L5
Quick Ship orders ship in 5 days in order quantities not to exceed 200 pieces.
NOTE: Orders received after noon are entered on the following day.
19-17/32"
[496mm]
48-7/16" [1230mm]
19-17/32" [496mm]
2-15/32" [63mm]
Dimensions
HBL Lamp Configurations
Dimensions for Top View
4-Lamp
27
No. of Lamps
4=4 Lamps
6=6 Lamps
Lamp Type
32=32W T8
Lamps (48")
Family
HBL
Power Receptacle
MP=Modular Power
Receptacle
(8)
Uplight
Blank=No Uplight
UPL=Uplight
NOTES:
(7)
Recommended when using motion sensor options.
(8)
Requires use of Modular cord and plug accessories.
(9)
L5HL (3000 initial) 5000K T8 lamps installed.
Lamping
Blank=No Lamps
L4=Lamps Installed 85+CRI 4100K
L5=Lamps Installed 85+CRI 5000K
L5HL=Lamps Installed 85+CRI 5000K,
High Lumen
(9)
No. of Lamps
4=4 Lamps
6=6 Lamps
8=8 Lamps
10=10 Lamps
Lamp Type
32=32W T8 Lamp (48" Long)
Series
HBL=Linear High Bay
Width
Blank=20" wide
4 & 6 Lamp
(nominal)
26" wide 8 & 10
Lamp (nominal)
Voltage
(1)
UNV=Universal 120/277 Voltage
UNC=Universal 347/480 Voltage
(EB8/PLUS only)
120V=120 Volt
277V=277 Volt
347V=347 Volt
Distribution
N=Narrow Beam (Standard)
M=Medium Beam
W=Wide Beam
Options
UPL=Uplight Apertures on Reflector
MP=Modular Power Receptacle
(Used for all Cord or Cord and
Plug options)
(2)
MWS=Modular Wiring System
(3)
MS=360° or 180° Motion Sensor installed
(120V through 347V, or 480V )
(1)
Packaging
U=Unit Pack
PALC=Palletized
In Carton
Options
Lamps Installed
L8835=T8 Lamp, 85CRI 3500K
L8841=T8 Lamp, 85CRI 4100K
L8850=T8 Lamp, 85CRI 5000K
HL=Add HL at end of lamp for high
lumen lamps, T8 only
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency Installed
NOTES:
(1)
Voltage must be specified when ordered with plugs or emergency ballasts. For MS option, indicate UNV (for 120V
or 277V), 347V or 480V.
(2)
Requires use of MC or MPC cord accessories, specify voltage for plugs.
(3)
Cannot be combined
with Modular Power Receptacle (MP). For MWS with MP, choose MP in fixture logic and then choose MWS.
(4)
T8 ballast
systems suitable for operation in ambient environments up 131°F (55°C) in uplight configuration.
(5)
Recommended when
using motion sensor options.
(6)
Can be used in high abuse applications such as gymnasiums.
Accessories (order separately)
HBL-SPM=Single Monopoint Hanger w/Hub
RH-1=Retrofit Hanger
FH-1=Fixture Hook
FL-1=Fixture Loop
Y- TOGGLE=Y Mounting Toggle, #2 Cable (Specify 10' or 30')
HBAYC-CHAIN/SET/U=(2) V-Hook Hanger, 36" Chain Sets
w/S-Hooks
MC3=3' Modular Power Cord
MPC3=3' Modular Power Cord & Plug (Specify Voltage)
MC6=6' Modular Power Cord
MPC6=6' Modular Power Cord & Plug (Specify Voltage)
MMS=360° or 180° Aisle Motion Sensor with Modular
Power Receptacle (120-277V)
(2)
WG/HBL6-4FT-B=4/6 Lamp Wireguard w/Clips
WG/HBL8-4FT-B=8 Lamp Wireguard w/Clips
Ballast Type
(4)
T8 Systems
EB8
=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8
/PLUS=T8 Electronic Instant Start.
High Ballast Factor >1.15.
Total Harmonic Distortion < 10%
ER8
=T8 Electronic Program Rapid Start.
(5)
Total Harmonic Distortion < 10%
ER8
/PLUS=T8 Electronic Program Start.
(5)
High Ballast Factor >1.15.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
No. of
Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
No. of
Ballast
1, 2 or 3
19-17/32" [496mm]
2-15/32" [63mm]
6-Lamp
2-15/32" [63mm]
25-1/4" [641mm]
8-Lamp
25-1/4"
[641mm]
48-7/16" [1230mm]
20-11/32" [517mm] 24-19/32" [625mm]
4/6 Lamp
2-15/32" [63mm]
25-1/4" [641mm]
8/10 Lamp
10-Lamp
Includes V Hangers for rapid installation
(6)
Distribution
Blank=Narrow Beam
W=Wide Beam