Specification Sheet

2GR8IC-217A 12 lbs.
2GR8IC-417A 12 lbs.
2GR8IC-2U6T8A 12 lbs.
2GR8IC-2U1-5/8A 12 lbs.
SHIPPING INFORMATION
Catalog No. Wt.
2GR8IC
Vi
sit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 8/14/18
ADF100878
NOTES:
(1)
An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.
(2)
Products
also available in non-US voltages and frequencies for international markets.
(3)
Not available when specifying
emergencies, voltage must be specific.
(4)
Standard off center ballast on 3 lamp fixtures.
(5)
2 lamps maximum
for U6T8 and U1-5/8.
(6)
Ballast Factor is 0.88 for 4 lamp 32W T8 fixtures.
(7)
Fifthlight ballast option not available.
(8)
For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit
www.coopercontrol.com.
(9)
0-10V ballast do not include DALI feature. Please select DALI ballast for use with Fifth
Light system.
(10)
Specification grade 0-10V dimming ballast are NEMA premium and CEE listed. They are compatible
with low mercury and energy saving lamps.
(11)
Specification Grade 0-10V ballast not offered in 3 or 4-lamp versions.
(12)
Standard 0-10V ballast not offered in 3 or 4-lamp versions
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject
to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
ORDERING INFORMATION
SAMPLE NUMBER: 2GR8IC-2U6T8A-UNV-EB81-U
Number of
Lamps
(4), (5)
2=2 Lamps
3=3 Lamps
4=4 Lamps
(Not included)
Wattage
17=17W T8 (24")
U6T8=32W (24")
(5), (6)
U1-5/8=31W T8 (24")
(5), (7)
Shielding
A=#12 Acrylic Pattern
A125=#12 Pattern Acrylic
(.125" Thick)
A19/156=#19 Pattern
Acrylic (.156" Thick)
PB1S=Silver Parabolic
Louver (1/2" x 1/2" x 1/2")
Options
GL=Single Element Fuse
GM=Double Element Fuse
Lamps=Lamps Installed
Flex=Flex Installed
EL=Emergency Installed
Width
2=2' Width
Series
R8=General
Purpose T8
Commercial
Troffer
(1)
Trim Type
G=Grid/Lay-in
(Standard)
Voltage
(2)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal Voltage
120-277
(3)
Type
IC=IC Rated
ACCESSORIES
EQ-CLIP-U=T-BAR Safety Earthquake Clips
(1)
FCTKA-22W-U=Field Installed Flange Kit
Trim Kit
Field
Convertible
Aluminum
FCTK A
22=2' x 2'
24=2' x 4'
24
Blank=Single
R=In Row
E=End Row
R W
N=Natural
W=White
U
U=Unit Pack
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
Ballast Type
EB8
=T8 Electronic Start.
Total Harmonic Distortion < 10%
EB8
/PLUS= T8 Electronic Start.
Total Harmonic Distortion < 10%.
High Ballast Factor > 1.15.
ER8
= T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
High Performance T8 Ballasts
HB8
=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HB8
L=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Low Ballast Factor .77 – .82
HB8
N=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Normal Ballast Factor 1.0
HB8
H=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
HR8
T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HR8
DIM=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Step Dimming. Ballast Factor .88
HR8
L=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Low Ballast Factor .71 – .79
HR8
H=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
0-10V Dimming Ballasts
(9)
5LTV8 =T8 0-10V Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 0.87
(12)
5LTVS8 =T8 0-10V Spec Grade Program
Rapid Start. Total Harmonic
Distortion < 10%. Ballast Factor 0.87
(10), (11)
Fifth Light DALI Ballasts
(8)
5LT8 =T8 DALI Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
Number of Ballasts
1=1 Ballast
2=2 Ballasts
3=3 Ballasts
Packaging
U=Unit Pack
PAL=Job
Pack, out of
carton
PALC=Job
Pack, in
carton