raditionally, these types of energy savings required coordination between the luminaire and a lighting control system.
Cruze delivers superior lighting with integrated occupancy and daylighting controls.
the benefits of traditional lighting controls, without complicated coverage planning or special wiring.
for new construction or retrofit, the Cruze delivers automatic ON to an energy saving light level,
ensuring lighting is turned OFF when the space is unoccupied.
integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will
adjust the light level based on reflected light beneath the sensor in a closed loop method.
daylight light levels and unoccupied light levels can be adjusted using the integrated sensor
remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02)
vides code compliant manual raise, lower, ON, OFF control.
Cruze with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box
default control settings.
it works:
As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level.
Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes).
If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable
light level is typically half of the occupied daylight level.
At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting.
C
L
Top View
Side Vi ew
4m
2 ft.]
4m
2 ft.]
0m
[0 ft.]
Coverage
Major Motion
3.3m
[10 ft.]
0m
[0 ft.]
0m
[0 ft.]
4m
[12 ft.]
4m
[12 ft.]
Reccomended Mounting Height 8–12 ft.
100
0
(DO)
Daylight Level
(DO)
Daylight Level
Timeout Value
(ES)
Energy Saver
Light Level
OccupiedUnoccupiedOccupiedUnoccupied
Energy Savings
Opportunities
(DU)
Unoccupied Level
Target light level default: 500 lux at 8 ft.
Remote
ISHH-01 Programming Remote
P
r
o
g
r
a
m
m
i
n
g
R
e
m
o
t
e
IS
H
H
-0
1
To
S
e
t
O
u
t
p
u
t
1. R
aise, Low
er o
r P
ress M
in.
5 0, 75, M
ax.
2. To save pres
s
S
E
T
3. S
e
l
ect
O
cc or
U
n O
cc
R
a
i
s
e
/
L
o
w
e
r
Tim
e
O
u
t
5
10
15
20
HI
LO
ES
SET
Occ
50
MIN
Un
Occ
MAX
75
Per
s
onal
Remo te
IS
H
H
-0
2
Raise
/
Lowe
r
S
C
E
N
E
MAX
75
50
MIN
Un
Occ
ES
Occ
To
S
elec t
S
c
e
nes
Pr
e
ss the S
C
EN
E
butt on.
The ligh
ti ng wi ll
adj u
st to
stor ed li ght l
ev
els. .
ISHH-02 Personal Control Remote
INTEGRATED SENSOR