Cut Sheet

PS519271EN page 2
September 22, 2022 2:34 PM
22GR LED
Order Information SAMPLE ORDER NUMBER: 22GR-LD5-27-F1-UNV-L835-CD1-U
Domestic Preferences
(1)
Rating Width/Length Trim Type Series
(3)
Door Frame LED Type LED Lumen Output
(4)
Shielding
[Blank]=Standard
BAA=Buy American Act
TAA=Trade Agreements Act
[Blank]=Standard
ATW-SW4=
Chicago Rated
22=2' x 2' G=Grid/Lay-in
(Standard)
(2)
G=Concealed T
G=Slot Grid
R=General
Purpose
Troffer
Standard=Flat White Steel
Door (Leave Blank)
(7)
FA=Flush White Extruded
Aluminum c/w Spring Latch
RA=Regressed White
Extruded Aluminum
FAN=Flush Natural Anodized
Extruded Aluminum
RAN=Regressed Natural
Anodized Extruded Aluminum
FAB=Flush Black Extruded
Aluminum
RAB=Regressed Black
Extruded Aluminum
LD5=LED 5.0 20=2000
(6)
24=2400
(6)
28=2800
32=3200
36=3600
40=4000
43=4300
50=5000
(5)
60=6000
(5)
70=7000
(5), (6)
85=8500
(5), (6)
90=9000
(5), (6)
F1=Pattern 12, Frosted
Acrylic, 0.095" thick
F125=Pattern 12, Frosted
Acrylic, 0.125" thick
A=Pattern 12, Clear
Acrylic, 0.095" thick
A125=Pattern 12, Clear
Acrylic, 0.125" thick
A19/156=Pattern 19,
Clear Acrylic, 0.156"
thick
(25)
FGW080=Frosted Smooth
Acrylic, 0.080" thick
Notes
(1) Only product congurations with
these designated prexes are built to be
compliant with the Buy American Act of
1933 (BAA) or Trade Agreements Act of
1979 (TAA), respectively. Please refer to
DOMESTIC PREFERENCES website for
more information. Components shipped
separately may be separately analyzed
under domestic preference requirements.
Notes
(2) An EQ
Grid Clip is
recommended for
all 9/16" ceiling
systems.
Notes
(3) DesignLights
Consortium
®
Qualied and
classied for DLC
Standard, refer to
www.designlights.
org for details.
Notes
(7) Only Standard door frames can
support wireguard accessory.
Notes
(4) Nominal lumen output. See
table for actual values. (5)
White tuning not available with
this model. (6) Not compatible
with WN driver.
Notes
(25) A19/156 lens creates
holographic effect on the
surface of the lens.
Voltage
(8)
Options Emergency CCT Factory Wiring Driver Type
347V=347 Volt
(10)
UNV=Universal
Voltage 120-277
(9)
48V=48 Volt Low-
voltage (Class 2)
(C)
120V=120 Volt
(11)
277V=277 Volt
(11)
GL=Single
Element Fuse
GM=Double
Element
Fuse
EL7W=7-watt 120V-277V emergency battery
pack
(12)
EL10W=10-watt 120V-277V emergency battery
pack
(12)
EL14W=14-watt 120V-277V emergency battery
pack
(12)
EL10WSD=10W emergency battery pack with
self-diagnostic installed
(12), (26)
EL14WSD=14W emergency battery pack with
self-diagnostic installed
(12), (26)
ELV7W=Low-voltage system, 7-watt emergency
battery pack
(C)
ELV14W=Low-voltage system, 14-watt
emergency battery pack
(C)
GTR2=Bodine Generator Transfer Relay
(13) , (14)
ETRD=Emergency Transfer Relay with dimming
control
(13)
L830=80CRI, 3000K
L835=80CRI, 3500K
L840=80CRI, 4000K
L850=80CRI, 5000K
L930=90CRI, 3000K
L935=90CRI, 3500K
L940=90CRI, 4000K
L950=90CRI, 5000K
L83050=80CRI 3000K-5000K
White Tuning
(15)
L93050=90CRI 3000K-5000K
White Tuning
(15)
L82765=80CRI 2700K-6500K
White Tuning
(15)
L92765=90CRI 2700K-6500K
White Tuning
(15)
A3/8-4/18GDIM=3/8" Flex with 0-10V Dimming Leads
Multiple other congurations available. See below
for details.
A3/8-5/18GDIM=Flex with 0-10V Dimming leads
and Blue for alternate wiring. See below for details.
CD=0-10V Driver (10%-100% Dimming)
HCD=0-10V Driver (1%-100% Dimming)
5LTD=DALI Driver (5%-100% Dimming)
(16)
5LTHD=DALI Driver (1%-100% Dimming)
LV=Low-voltage System Driver (0%-100%
Dimming)
(C)
SD=Step Dimming Driver (50% or 100%
Dimming)
(16)
LH=Lutron HiLume (LDE1 series) 1%-100%
EcoSystem Driver with Soft-on Fade to
Black dimming
(F)
W2A=White Tuning, 2 ch, Intensity and
CCT Control
(17)
SR=Sensor-ready Driver (1%-100%
Dimming)
Notes
(8) Products also
available in non-US
voltages and frequencies
for international markets.
(9) Not available when
specifying emergencies,
voltage must be
specic. (10) 347V is
not available with the
W2A driver. (11) Must
specify voltage as 120V
or 277V when ordering
GTR2 option. (C) Consult
WaveLinx Low-Voltage
or DLVP system pages
for additional details and
compatibility.
Notes
(12) Factory installed with integral test switch/indicator/
laser test. For approximate delivered lumens multiply
the lumens per watt of the desired xture by the wattage
of the emergency battery pack (100 lm/W x 7=700
lumens). IES-format photometry for luminaire under
emergency operation available. Battery option increases
total height by 1 inch. (13) Used to bypass local control
during outage. Must be used in conjunction with UL 1008
device (provided by others). GTR2 option includes 2
relays on xtures with dimming drivers. ETRD option only
requires one relay when used on a dimming xture. (14)
Must specify voltage as 120V or 277V when ordering
GTR2 option. (26) EL10WSD and EL14WSD not available
with 347V.
(C) Consult WaveLinx Low-Voltage or DLVP system
pages for additional details and compatibility.
Notes
(15) White tuning provides
correlated color temperatures
(CCT) between 3000K (warm) to
5000K (cool) or 2700K (warm)
to 6500K (cool). Must be used in
conjunction with W2A.
Flexible Metal Conduit Options
Flex options available for 0-10V dimming control, DALI dimming
control, emergency and night light functions. 72-inch factory-
installed and pre-wired to driver, tted to luminaire housing
access plate with 90° enclosed FMC connector. Not all options
may be combined and installation ratings vary by type.
A3/8-4/18GDIM series notes: Factory installed dimming option
3/8” flexible metal conduit with 2-#18 power and ground wires
and 2-#18 UL-listed jacketed 0-10V +/- control wires. Meets
UL 66, 83, 1479, 1569, 1581, 2556. NEC® 250.118, 300.22(C),
392, 396, 330, 501, 502, 503, 530, 504, 505, 518, 520, 530, 645,
72; Federal Specication A-A-59544 (formerly J-C-30B); all
applicable OSHA and HUD Requirements. UL Classied 1-, 2-, and
3-hour through penetration with applicable re stop product (not
included). May be surface mounted, shed and/or embedded
in plaster. Cable tray and approved raceway rated, install per
NEC®; Environmental Air-Handling Space Installation per NEC®
300.22(C).
Notes
(16) Step Dim (Bi Level) and DALI only available in
3600 lumen and above. (17) White tuning provides
correlated color temperatures (CCT) between
3000K (warm) to 5000K (cool) or 2700K (warm)
to 6500K (cool). Must be used in conjunction
with W2A.
Integrated options must be used in conjunction
with the associated system and may not be
compatible with other options or accessories.
Please refer to the following: (C) Consult
WaveLinx Low-Voltage or DLVP system pages for
additional details and compatibility. (F) Consult
Marketplace Options - Lutron system pages for
additional details and compatibility. Compatible
only with driver series shown, and may require two
or more drivers. Requires eld commissioning to
operate or dim. Contact Lutron at www.lutron.com
No.of Drivers Options Integrated Sensing Systems Packaging Accessories
(24)
1=1 Driver
2=2 Drivers
PAF=Painted After Fabrication
G1=Gasket, Door Frame and
Housing
G2=G1 plus Gasket between
Lens and Door
G3=G1 and G2 plus Gasketing
on Mounting Surface of
Fixture Trims
(18), (19)
[Blank]=No Sensor
WAA=WaveLinx Wireless Integrated Sensor
(20), (A)
WAB=WaveLinx Lite Wireless Integrated Sensor
(21), (B)
WLA=Low-voltage Integrated Sensor
(22), (C)
SVPD1=0-10V Stand-alone Integrated Sensor
(21), (D)
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
EQ-CLIP-U=T-BAR Safety Earthquake Clips
(23)
DF-22W-U=2' x 2' Drywall Frame Kit
SK-22-WS=2' x 2' Shallow Surface Mount Kit
SK-22-WT=2' x 2' Tall Surface Mount Kit
ISHH-01=Programming Remote for Integrated
Sensor
(D)
ISHH-02=Personal Control Remote for
Integrated Sensor
(D)
Notes
(18) Gasketing only available
with aluminum door frame. (19)
Gasketing minimum .125.
Notes
(20) WAA sensor to be used with CD or W2A driver. (21) WAB and SVPD1 sensor to be used with CD driver. (22) WLA
sensor to be used with LV driver.
Integrated options must be used in conjunction with the associated system and may not be compatible with other
options or accessories. Please refer to the following: (A) Consult WaveLinx system pages for additional details and
compatibility. (B) WaveLinx Lite devices are not currently compatible with the WaveLinx Wireless Area Controller.
Consult WaveLinx Lite system pages for additional details and compatibility. (C) Consult WaveLinx Low-Voltage or
DLVP system pages for additional details and compatibility. (D) Consult SVPD series system pages for additional
details and compatibility.
Notes
(23) An EQ Grid Clip is recommended for all 9/16"
ceiling systems. (24) Accessories sold separately will
be separately analyzed under domestic preference
requirements. Consult factory for further information.
(D) For use with SVPD sensor only. Consult SVPD series
system pages for additional details and compatibility.