Manual

Operating Instructions – MOVIMOT® MM03C - MM3XC
97
8
Selectable special functions MM..C-503-30
Startup with Integrated AS-Interface
Special function 3
MOVIMOT
®
with adjustable current limitation (switchable via AS-i bit "speed f1/
speed f2"), with reduction of frequency if exceeded
Function descrip-
tion
The current limitation can be set via switch f2. The AS-i bit "speed f1/speed f2" can be
used to toggle between maximum current limit and the current limitation set via switch f2.
Response after
reaching the cur-
rent limitation
After reaching the current limit, the unit reduces the frequency using the current lim-
itation function and if necessary stops the ramp to prevent the current from increas-
ing.
If the unit operates at the current limitation, the status is displayed through rapid
green flashing of the status LED.
In-system values
for setpoint f2/mini-
mum frequency
Switching via AS-i "speed f1/speed f2" between setpoint f1 and setpoint f2 is no
longer possible.
Adjustable current
limits
Selection of cur-
rent limitation via
AS-i bit "speed f1/
speed f2"
51861AXX
6
7
85
2
1
ON
S4
4
5
63
3
4
5
6
7
8
Switch f2
Detent position 012345678910
I
max
[%] of I
N
60 70 80 90 100 110 120 130 140 150 160
AS-i bit "speed f1/speed f2" = 0 AS-i bit "speed f1/speed f2" = 1
Current limitation 160% Current limitation via switch f2
00
I