Selectable special functions MM..C-503-30
Startup with Integrated AS-Interface
8.5 Selectable special functions MM..C-503-30
Overview of
selectable special
functions
Decimal
value
Brief description Limitations see page
0 Basic functionality, no special function selected – –
1 MOVIMOT
®
with increased ramp times – page 96
2 MOVIMOT
®
with adjustable current limitation
(fault if exceeded)
–
page 96
3 MOVIMOT
®
with adjustable current limitation
(switchable via terminal f1/f2)
–
page 97
4 Not possible with MOVIMOT
®
with integrated AS-Interface –
5 Not possible with MOVIMOT
®
with integrated AS-Interface –
6 MOVIMOT
®
with maximum 8 kHz PWM fre-
quency
–
page 99
7 MOVIMOT
®
with rapid start / stop Rapid stop not possible page 99
8 MOVIMOT
®
with minimum frequency 0 Hz – page 100
9 Not possible with MOVIMOT
®
with integrated AS-Interface –
10 MOVIMOT
®
with minimum frequency 0 Hz and
reduced torque at low frequencies
–
page 101
11 Monitoring of supply phase fault is deactivated – page 101
12 Not possible with MOVIMOT
®
with integrated AS-Interface –
12 to 15 Not assigned – –
00