Manual
Operating Instructions – MOVIMOT® MM03C - MM3XC
91
8
Description of the controls
Startup with Integrated AS-Interface
DIP switches S3
and S4
DIP switch S3:
DIP switch S4:
51858AXX
S3 1 2 3 4 5 6
Message Motor
protection
Motor
rating class
PWM
frequency
No-load
damping
Motor type Brake release
without
Enable
ON Off
Motor one
size smaller
Variable
(16, 8, 4
kHz)
On
SEW DZ
motor:
1)
1) only available in Brazil
On
OFF On adapted 4 kHz Off IEC motor Off
S4 1 2 3 4 5 6
Message Control process Speed
monitoring
Selection of options
2
0
2
1
2
2
2
3
ON V/f On 1111
OFF VFC Off 0000
00