Manual
66
Operating Instructions – MOVIMOT® MM03C - MM3XC
7
Selectable special functions MM..C-503-00
Startup of Standard Design
Special function 7
MOVIMOT
®
with rapid start/stop
Function descrip-
tion
• The pre-magnetization time is fixed at 0 s, independent of whether MOVIMOT
®
is
operated in bus or terminal mode.
• No pre-magnetization is carried out at the start of the release to begin the accelera-
tion at the setpoint ramp as quickly as possible.
• The subsequent behavior of MOVIMOT
®
is dependent on the operating mode and
whether a mechanical brake is connected.
05602AXX
1
6
7
85
4
3
2
ON
S2
6
7
85
Special function 7
Rapid start/stop
Operating mode
Bus opera-
tion
Terminal
operation
Mechanical brake con-
trolled by...
...MOVIMOT
®
...relay out-
put
...MOVIMOT
®
...relay out-
put
Relay function Ready relay
Brake relay
(see page
75)
Ready relay
Brake relay
(see page
75)
00
I