Manual
Operating Instructions – MOVIMOT® MM03C - MM3XC
63
7
Selectable special functions MM..C-503-00
Startup of Standard Design
Changing the
parameters in
MOVITOOLS
®
Open MOVITOOLS
®
/Shell as follows
• Select "MOVIMOT
®
" equipment class [1]
• Under program execution, select "Shell" [2]
After opening MOVITOOLS
®
/Shell, the following parameters are accessible. They can
be changed and stored in the unit.
• The factory setting is activated as soon as special function 4 is activated via DIP
switches. If the selected special function via DIP switches remains unchanged after
switching off the 24 V operating voltage, the reactivation will use the last known val-
ues from EEPROM.
• The start frequency is fixed at 0.5 Hz, the stop frequency at 3 Hz.
• If the set setpoint or the maximum frequency is lower than the set minimum frequen-
cy, the minimum frequency becomes active.
• The indexes are only evaluated with this special function.
05595AEN
Name Area Index Parameter
number
Step width
Ramp up 0.1...1...2000 [s] 8807 130 0.1 s – 1 s: 0,01
1 s – 10 s: 0,1
10 s – 100 s: 1
100 s – 2000 s: 10
Ramp down 0.1...1...2000 [s] 8808 131
Minimum frequency 2...100 [Hz] 8899 305 0.1
Maximum frequency
1)
2...100 [Hz] 8900 306 0.1
Current limit 60...160 [%] 8518 303 1
Pre-magnetization time 0...0.4...2 [s] 8526 323 0.001
Post-magnetization time 0...0.1...2 [s] 8585 732 0.001
Parameter lock On/Off 8595 803 –
Factory setting Yes/No 8594 802 –
Delay time (P501/503)
Speed monitoring
0.1...1...10.0 [s] 8558 501 0.1
Brake release time 0..2 [s] 8749 731 0.001
Slip compensation
2)
0..500 [1/min] 8527 324 0.2
Factory setting = bold
1) Example: Maximum frequency = 60 Hz
Bus setpoint = 10 %
Frequency setpoint = 6 Hz
2) If the special function setting is changed, the value is set to the rated motor slip.
[1]
[2]
00
I