Manual
58
Operating Instructions – MOVIMOT® MM03C - MM3XC
7
Selectable special functions MM..C-503-00
Startup of Standard Design
7.5 Selectable special functions MM..C-503-00
Overview of
selectable special
functions
Decimal
Value
Brief description Intended oper-
ating mode
see
page
Replaces
MOVIMOT
®
B
type
Bus Termi-
nals
0 Basic functionality, no special function selected X X – –
1 MOVIMOT
®
with increased ramp times
XX
page
59
MM..B-503-01
2 MOVIMOT
®
with adjustable current limitation
(fault if exceeded)
XX
page
59
MM..B-503-02
3 MOVIMOT
®
with adjustable current limitation
(switchable via terminal f1/f2)
XX
page
60
MM..B-503-05
4 MOVIMOT
®
with bus parameter setting
X–
page
62
–
5 MOVIMOT
®
with motor protection via TH
X–
page
64
MM..B-503-14
(partially)
6 MOVIMOT
®
with maximum 8 kHz PWM fre-
quency
XX
page
65
MM..B-503-13
7 MOVIMOT
®
with rapid start / stop
XX
page
66
–
8 MOVIMOT
®
with minimum frequency 0 Hz
XX
page
68
–
9 MOVIMOT
®
for hoist applications
XX
page
69
–
10 MOVIMOT
®
with minimum frequency 0 Hz and
reduced torque at low frequencies
XX
page
71
–
11 Monitoring of supply phase fault is deactivated
XX
page
71
–
12 MOVIMOT
®
with quick start/stop and motor pro-
tection via TH
XX
page
72
–
13 to 15 Not assigned – – – –
00
I