Manual
40
Operating Instructions – MOVIMOT® MM03C - MM3XC
6
Connection options with integrated AS-Interface
Electrical Installation with Integrated AS-Interface
B Design with AZSK plug (3 x M12 connector):
Design B1 B2 B3
Type designation MM../RC.A/AZSK MM../RC.A/AZSK MM../RC.A/AZSK
Switch S5 110
24 V supply Black AUX-PWR cable Black AUX-PWR cable
(double tap)
Yellow AS-i cable
AS-i connection Yellow AS-i cable Yellow AS-i cable (double
tap)
Yellow AS-i cable
Mains connection Terminals Terminals Terminals
Sensor connection M12 plug connector M12 plug connector M12 plug connector
Additional
information
page 43 page 43 page 43
52002AXX
[1] Mains
2 x DI
2 x DI
AS-i (YE)
AUX-PWR
(BK)
B1
B2
AS-i (YE)
AUX-PWR (BK)
B3
AS-i (YE)
[1]
[1]
2 x DI
[1]
• The designs listed above are also valid for mounting the MOVIMOT
®
inverter with