Manual

156
Operating Instructions – MOVIMOT® MM03C - MM3XC
13
Assignment of internal braking resistors
Technical Data with Integrated AS-Interface
13.2 Assignment of internal braking resistors
13.3 Assignment of external braking resistors
13.4 Resistance and assignment of the brake coil
13.5 URM voltage relay
MOVIMOT
®
type Braking resistor Part number
MM03 to MM15 BW1 822 897 3
1)
1) 2 screws M4 x 8, included in delivery
MM22 to MMM3X BW2 823 136 2
1)
MOVIMOT
®
type Braking resistor Part number Protective guard
MM03 to MM15
BW200-003 826 267 5 813 152 X
BW200-005 826 270 5 813 152 X
BW150-010 802 285 2
MM22 to MMM3X
BW100-003 826 266 7 813 151 1
BW100-005 826 269 1 813 151 1
BW068-010 802 287 0
Motor Brake Resistance of the brake coil
1)
1) Rated value measured between the red connection (terminal 13) and the blue connection (terminal 15) at
20 °C, temperature-dependent fluctuations in the range -25 % / +40 % are possible.
DT71 BMG05 277 (230 V)
DT80 BMG1 248 (230 V)
DT90 BMG2 216 (230 V) / 54.2 (110 V)
DV100/DT100 BMG4 43.5 (110 V)
Voltage relay
Part number 827 601 3
Function Implements quick application of mechanical brake
Enclosure IP20
Rated voltage V
rated
36 V
DC
...167 V
DC
(brake coil 88 V
AC
...167 V
AC
)
Brake current I
N
0.75 A
Ambient temperature -25...60 °C
Switch-off time t
off
(separation on DC
side)
approx. 40 ms
P
i
f
kVA
Hz
n