Manual

Operating Instructions – MOVIMOT® MM03C - MM3XC
129
10
Diagnostics of MOVIMOT® standard design
Diagnostics
Fault code 89
Thermal overload of brake coil or
brake coil defective
Extend the set ramp time
Brake inspection (see the section "Inspection and Maintenance")
Contact SEW service
If the fault should occur shortly after the initial enable, check the combination of drive (brake
coil) and MOVIMOT
®
frequency inverter.
For combinations of "MOVIMOT
®
and motor with one lower power increment," check the
position of DIP switch S1/6.
Reset the fault by switching off the 24 V
DC
supply voltage or use MOVILINK
®
.
Fault code 91
Communication error between field-
bus gateway and MOVIMOT
®
(this
fault is generated by the bus mod-
ule)
Check electrical connection between fieldbus gateway and MOVIMOT
®
(RS-485)
The fault is automatically reset after removing the cause, a reset via control word is not pos-
sible.
Faults Cause / solution