Manual
Operating Instructions – MOVIMOT® MM03C - MM3XC
101
8
Selectable special functions MM..C-503-30
Startup with Integrated AS-Interface
Special
function 10
MOVIMOT
®
with reduced torque at low frequencies
Function descrip-
tion
• The drive builds up only a reduced torque due to a reduction in slip and active current
at low speeds (see following figure):
• Minimum frequency = 0 Hz (see special function 8 on page 68)
Special
function 11
Deactivation of phase fault control
Function descrip-
tion
• Phase control does not take place if the special function is activated.
• This is meaningful, for example, for supply systems with brief asymmetry.
51868AXX
6
7
85
2
1
ON
S4
4
5
63
50907AXX
[1] Maximum torque with VFC operation
[2] Maximum torque with activated special function
M
5
[1]
[2]
10 15
f
[
Hz
]
52123AXX
6
7
85
2
1
ON
S4
4
5
63
00
I