Owner manual

9
Vibrator Model
Relub. Interval *
(Hours)
Grease Amount
Per Brg. (Ounces)
Initial Grease Fill
Per Brg. (Ounces)
2 Pole
BL 24/25-10/2 1600 0.2 0.4
BL 24/25-13/2 1400 0.3 0.6
BL 30 ALL 700 0.4 0.9
BL 40-30/2 650 0.5 1.2
BL 40-40/2 600 0.7 1.9
BL 50-50/2 200 0.6 2.8
4 Pole
BL 24/25-11/4 3500 0.2 0.4
BL 24/25/-14/4 3300 0.3 0.6
BL 30 ALL 3100 0.5 1.1
BL 40-35/4 2700 0.6 1.4
BL 45-45/4 2200 0.8 2.1
BL 50-55/4 1800 1.1 3.2
BL 50-65/4, -75/4 1600 1.3 3.9
BL 60 ALL 800 1.7 5.6
BL 75-130/4 350 1.3 7.1
6 Pole
BL 24/25-8/6 5800 0.2 0.4
BL 24/25-11/6 4800 0.3 0.6
BL 30 ALL 5000 0.5 1.1
BL 40 ALL 4300 0.7 1.4
BL 45 ALL 4100 0.9 2.1
BL 50-60/6 3800 1.1 3.2
BL 50-75/6 3400 1.3 3.9
BL 60 ALL 2600 1.9 5.6
BL 75 ALL 1800 2.3 7.1
8 Pole
BL 30 ALL 7000 0.5 1.1
BL 40-17/8 6500 0.7 1.4
BL 45 ALL 6000 0.9 2.1
BL 50-45/8 5500 1.1 3.2
BL 50-57/8 5000 1.1 3.9
BL 60 ALL 4500 2.1 5.6
BL 75-150/8 3000 2.3 7.1
* Relubrication intervals are based on continuous operation in ambient temperatures up to 68°F
(20° C) and should be reduced for increases in ambient temperature as follows: 77°F (25° C) x
.8, 86°F (30° C) x 0.65, 95°F (35° C) x 0.5, 104°F (40° C) x 0.4. Above 104°F (40° C) consult
our Technical Department.
Factory recommended grease for Invicta vibrators is EXXON UNIREX N2 or N3.
NOTE: The above relubrication intervals are for guidance only
and may be shortened or
lengthened, if necessary, in view of actual field experience by the end user.
Table 3: Bearing Relubrication Intervals and Amounts