Specification Sheet
6
RV
3" THROUGH 8"
A
B
Size Product No. Part No. a b
3" 103810 3RV-SC 1
9
⁄16"6
5
⁄8"
4" 104810 4RV-SC 1
9
⁄16"7
5
⁄8"
5" 105810 5RV-SC 1
9
⁄16"8
5
⁄8"
6" 106810 6RV-SC 1
9
⁄16"9
5
⁄8"
7" 107810 7RV-SC 1
9
⁄16"10
3
⁄4"
8" 108810 8RV-SC 1
9
⁄16"11
3
⁄4"
STORM COLLAR
NOTE: See instructions for use/limitations
QUICK GRIP FIRESTOP/SPACER
A
A
Size Product No. Part No. a
3" 103406 3RV-FSP 9"
4" 104406 4RV-FSP 10"
5" 105406 5RV-FSP 11"
6" 106406 6RV-FSP 12"
UL Model
Size Product No. Part No. a
3" 103404 3RV-FSPU 9"
4" 104404 4RV-FSPU 10"
5" 105404 5RV-FSPU 11"
6" 106404 6RV-FSPU 12"
NOTE: UL-listed model includes an attached spacer ring to ensure 1” clearance to combustibles.
A
B
C
Size Product No. Part No. a b c
3" 103460 3RV-GC 3
3
⁄4"8
1
⁄2"2
3
⁄8"
4" 104460 4RV-GC 4
3
⁄4"9
1
⁄2"2
3
⁄8"
5" 105460 5RV-GC 5
3
⁄4"10
1
⁄2"2
3
⁄8"
6" 106460 6RV-GC 6
3
⁄4"11
1
⁄2"2
3
⁄8"
7" 107460 7RV-GC 7
3
⁄4"12
1
⁄2"2
3
⁄8"
PIPE COLLAR
NOTE: May be used as firestop for openings in floors, ceilings and walls.
TOPS, SUPPORTS AND FIRESTOPS
FLASHINGS AND STORM COLLAR
Flat to 6/12
Size Product No. Part No. a b c d
3" 103825 3RV-AF 3
1
⁄2"14
7
⁄8"12
1
⁄4"6
11
⁄16"
4" 104825 4RV-AF 4
1
⁄2" 16" 13
1
⁄4"7
3
⁄4"
5" 105825 5RV-AF 5
1
⁄2"16
15
⁄16"14
1
⁄4"8
7
⁄8"
6" 106825 6RV-AF 6
1
⁄2" 18" 15
1
⁄4" 10"
7" 107825 7RV-AF 7
1
⁄2"19
1
⁄8" 16" 11
1
⁄8"
8" 108825 8RV-AF 8
1
⁄2"20
1
⁄4"16
15
⁄16"12
1
⁄4"
ADJUSTABLE ROOF FLASHING
A
B
C
Size Product No. Part No. a b c
3" 103820 3RV-TFA 8
3
⁄4" 11" 19
1
⁄2"
4" 104820 4RV-TFA 8
3
⁄4" 11" 19
1
⁄2"
5" 105820 5RV-TFA 8
3
⁄4" 11" 19
1
⁄2"
6" 106820 6RV-TFA 8
3
⁄4" 11" 19
1
⁄2"
7" 107820 7RV-TFA 8
3
⁄4" 14" 22"
8" 108820 8RV-TFA 8
1
⁄4"15
3
⁄16" 23"
TALL CONE ADJUSTABLE ROOF FLASHING
A
B
C
Size Product No. Part No. a b c
3" 103815 3RV-TF 12" 7
1
⁄2"16
1
⁄2"
4" 104815 4RV-TF 12" 7
1
⁄2"16
1
⁄2"
5" 105815 5RV-TF 12" 7
1
⁄2"16
1
⁄2"
6" 106815 6RV-TF 12" 11" 19
1
⁄2"
7" 107815 7RV-TF 12" 11" 19
1
⁄2"
8" 108815 8RV-TF 12" 11" 19
1
⁄2"
TALL CONE FLAT ROOF FLASHING
6/12 to 12/12
Size Product No. Part No. a b c d
3" 103830 3RV-AF12 3
1
⁄2" 18" 15
1
⁄4"10
1
⁄4"
4" 104830 4RV-AF12 4
1
⁄2"19
1
⁄8" 16" 11
1
⁄8"
5" 105830 5RV-AF12 5
1
⁄2"20
1
⁄4"16
15
⁄16"12
1
⁄4"
6" 106830 6RV-AF12 6
1
⁄2"24
1
⁄4" 20" 15
5
⁄8"
7" 107830 7RV-AF12 7
1
⁄2"24
1
⁄4" 20" 15
5
⁄8"
8" 108830 8RV-AF12 8
1
⁄2" 25" 19
1
⁄2"17
1
⁄8"
- Used to provide a weather proof seal to pipe above roof line
- Used above the Flashing
- Seal inner edge with hi-temp silicone sealant
- Used to protect combustible materials where the pipe passes through a ceiling or wall
- Provides a decorative/finished appearance
- Pipe collar also acts as a firestop
- Used where the vent passes through a roof
- Adjustable to 6/12 pitch
- Used where the vent passes through a roof
- Used on flat roof surfaces