Specification Sheet

5
RV
3" THROUGH 8"
5
Size Product No. Part No. a b
3" 103800 3RV-RT 6" 3
1
4"
4" 104800 4RV-RT 8" 4
1
4"
5" 105800 5RV-RT 10" 5
1
4"
6" 106800 6RV-RT 12" 6
1
4"
7" 107800 7RV-RT 14" 7
1
2"
8" 108800 8RV-RT 16" 8
1
2"
TOP (BIRD PROOF*)
TOPS, SUPPORTS AND FIRESTOPS
A
B
C
Size Product No. Part No. a b c
3" 103802 3RV-HWT 3" 8" 5
1
2"
4" 104802 4RV-HWT 4" 10" 6"
5" 105802 5RV-HWT 5" 12" 7"
6" 106802 6RV-HWT 6" 14" 7
1
2"
HI-WIND TOP
Support
Size Product No. Part No. a Plate Dim
3" 103400 3RV-GVS 3
5
8" 17" x 10"
4" 104400 4RV-GVS 4
5
8" 17" x 10"
5" 105400 5RV-GVS 5
5
8" 17" x 12"
6" 106400 6RV-GVS 6
5
8" 17" x 12"
7" 107400 7RV-GVS 7
5
8" 17" x 14"
8" 108400 8RV-GVS 8
5
8" 17" x 14"
A
support plate
cleat
SUPPORT ASSEMBLY
Size Product No. Part No. a
3" 103402 3RV-GVSB 3
5
8"
4" 104402 4RV-GVSB 4
5
8"
5" 105402 5RV-GVSB 5
5
8"
6" 106402 6RV-GVSB 6
5
8"
7" 107402 7RV-GVSB 7
5
8"
GAS VENT SUPPORT COLLAR & HARDWARE
- These tops cannot be used for wood burning applications
- Helps prevent rain and debris from entering the vent
- External screen prevents entry of most bird species
- Used in high wind environments
- Improves flue gas flow to prevent downdrafts
- Support Plate should be installed above the joist
- Support Plate also serves as a firestop
- Will support a maximum of 60' of gas vent
1" MIN
DIM A
Size Product No. Part No. a
3" 103431 3RV-WB 3
1
2" min
4" 104431 4RV-WB 4
1
2" min
5" 105431 5RV-WB 5
1
2" min
WALL BAND
A
B
Size Product No. Part No. a b
3" 187703 3RV-WT 3
5
8"7"
4" 187704 4RV-WT 4
5
8"8
1
4"
5" 187705 5RV-WT 5
5
8"9
1
2"
6" 187706 6RV-WT 6
5
8"10
3
4"
7" 187707 7RV-WT 7
3
4" 11"
8" 187708 8RV-WT 8
3
4"12
1
2"
WALL THIMBLE
NOTE: Adjusts from 4
1
8" to 7" to fit thickness of wall.
A
4
Size Product No. Part No. a
3" 103430 3RV-WS/B 3
5
8"
4" 104430 4RV-WS/B 4
5
8"
5" 105430 5RV-WS/B 5
5
8"
6" 106430 6RV-WS/B 6
5
8"
7" 107430 7RV-WS/B 7
5
8"
8" 108430 8RV-WS/B 8
5
8"
WALL SUPPORT/BAND ASSEMBLY
Framing Size
Size Product No. Part No. a & b
3" 103461 3RV-FS 5
1
2"
4" 104461 4RV-FS 6
1
2"
5" 105461 5RV-FS 7
1
2"
6" 106461 6RV-FS 8
1
2"
GAS VENT FIRESTOP SPACER
A
B
- Used to ensure clearance to combustibles is maintained
- Wall Thimble also serves as a firestop
- Adjusts from 4 - 1/8" to 7" to fit thickness of wall
- Used to stabilize the pipe against an outside wall
- Must be installed just above the Tee and every 6' thereafter
- Used to stabilize the pipe against an outside wall
- Must be installed just above the Tee and every 6' thereafter
- Used to protect combustible materials where pipe passes through a ceiling or wall
- Extended bottom flange