Instruction manual

Instruction Manual
Mobile thermal drilling
© Copyright by Flowdrill GmbH Olbrichtstr.18 69469 Weinheim
5
5. Use and general application
5.1. Mains power
Please check the mains voltage first. The mains voltage indicated on the hand drill must correspond
with the electric mains supply.
5.2. Mounting the drill on the drill stand
1. If necessary loosen clamping nut (socket, hexagonal socket head) of the circular clamp.
2. Insert the hand drill unit vertically into the collar as far as the stop.
3. Now hand tighten the clamping screw.
Should the drill be pushed upwards out of the collar during drilling because of the
axial force occurring, immediately stop the drilling process and repeat steps 1-3.
NOTE
Make sure that the surface on which the drill stand is placed is level. If necessary the base plate of
the drill stand must be fixed firmly to this surface with suitable screw fasteners
5.3. Deactivating the percussion stage
When using a hammer drill, the hammer function must be deactivated for thermal drilling and
flowtapping. Switch the drill over to the normal drill function.
Percussion stage ON
Percussion stage OFF