6.4. Guide system
Regularly check the guide system. This must if necessary be lubricated or readjusted. To readjust
please loosen the lock nuts (12) and cylindrical head screws (13) of the guide rail (2) and evenly
tighten the adjustment screws (11). Then retighten first the cylindrical
head screws and then the lock nuts.
Items (2, 11, 12, 13) according to exploded drawing Section 9.
6.5. Conversion for left hand operation
The capstan can be easily converted for left hand operation. To do this raise the guides to the upper
stop and then loosen the cross-head screw (7) and remove this together with the washer (18).
Completely remove the shaft (6) from the capstan and mount this in the reverse order from the left.
Items (6, 7, 18) according to exploded drawing Section 9.
6.6. Switches and cables
Regularly check switches, cables and anti-kink protection for damage.
The cable must not come into contact with the hot component or tool surface!
Repairs should only be carried out by an authorised specialist firm.
NOTE
The tool life depends among other things on:
- Process time
- Material thickness
- Material type (e.g. steel versus stainless steel)
- Care and maintenance
- Condition of the accessories: in particular tool holder and collet