12. Technical Specifications
P 3000 S P 3300 S
HWA 3300 S
P4000S
HWA 4000 S
Mains voltage V 230 ~ 1
Frequency Hz 50
Rated output W 900 1100 1300
Rated current A 3.6 4.5 4.5
Fuse protection min. (time-lag or B-type circuit breaker) A 10 10 10
Running capacitor PF 16 16 20
Rated speed min
-1
2800 2800 2800
Pump capacity max. l/h 3000 3300 4000
Delivery head max. m 43 45 48
Delivery pressure max. bar 4.3 4,5 4.8
Max. suction head m 7 8 8
Temperature of the primed medium max. °C 35 35 35
Ambient temperature °C 5 ... 40 5 ... 40 5 ... 40
Degree of protection IP X4 X4 X4
Protection class I I I
Insulation class B B B
Materials
Pump casing
Pump shaft
Impeller
Stainless steel
Stainless steel
Noryl
Stainless steel
Stainless steel
Noryl
Stainless steel
Stainless steel
Noryl
Connections
Intake port (female thread)
Discharge port (male thread)
1"
1"
1"
1"
1"
1"
Hydromat
Cut-in pressure approx. bar 1.5 1.5 1.5
Dimensions (without connections)
Length
Width
Height
mm
mm
mm
470
250
300
470 / 470
250 / 250
300 / 415
470 / 470
250 / 250
300 / 415
Weights
Dry weight
Weight filled with water
kg
kg
10.1
11.6
10.2 / 11.5
11.7 / 13
10.5 / 11.8
12.0 / 13.3
Noise emission values (at max. pressure)
Sound power level L
WAm
Sound pressure level L
WAd
dB (A)
dB (A)
89
94
83
90
86
89
Max. length of extension cable
at 3 x 1.0 mm
2
lead cross-section
at 3 x 1.5 mm
2
lead cross-section
m
m
30
50