User Manual
17
ENGLISH
2. Open pressure line (open tap or
spray nozzle) and drain water com-
pletely.
3. Drain pump completely; to do so
remove the drain plug from the
pump
4. Disconnect suction and pressure
lines from the pump.
5. Store pump in a frost-free location
(at least 5 °C).
A
Danger!
Prior to all servicing:
1. Turn OFF.
2. Unplug.
3. Ensure that pressure is relieved
from the pump and connected
accessories.
8.1 Locating the Fault
Pump does not run:
Pump not turned ON.
• Start pump at the ON/OFF
switch.
Hydromat has cut out.
• Press the reset button.
If no water is pumped after
approx. 10 seconds, press and
hold reset button until Water
emerges.
No mains voltage.
• Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
• Use only extension cables with
sufficient lead cross section (see
"Technical Specifications").
Motor overheated, motor protection
relay tripped.
• After cooling off the pump will
start again.
• Ensure sufficient ventilation, keep
vent slots clear.
• Observe max. temperature of the
pumped medium.
Motor hums but does not start.
• With the motor turned OFF, put
screwdriver or similar through the
fan cover's ventilation slots and
turn the fan.
Pump blocked or out of order.
• Disassemble pump and clean.
• Clean diffusor, replace if neces-
sary.
• Clean impeller, replace if neces-
sary.
Pump does not prime correctly or
runs very noisily:
Lack of water.
• Ensure there is a sufficient water
supply.
Suction line leaky.
• Seal suction line, tighten screw
fittings.
Suction head too high.
• Observe max. suction head.
• Install check valve, fill suction line
with water.
Suction strainer (optional acces-
sory) blocked.
• Clean, replace if necessary.
Check valve (optional accessory)
blocked.
• Clean, replace if necessary.
Water leaks between motor and
pump, Duocone seal worn.
• Replace Duocone seal.
Pump blocked or out of order.
• see above.
Pressure too low:
Suction line leaky or too much suc-
tion head.
• see above.
Pump blocked or out of order.
• see above.
A
Danger!
Repairs to electric tools must
only be carried out by a qualified
electrician!
Electric tools in need of repair can be
sent to an authorized service center in
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.
The packaging material of the pump is
100 % recyclable.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
For this pump the following accessories
are available from your dealer.
3
Note:
Illustrations and stock numbers
are shown at the end of this manual.
A Pump Installation Package,
(MSS 310 – HWA/P), complete with
double nipple, check valve, filter
short, washable filter cartridge, spi-
ral hose assembly 1 m, thread seal-
ing tape.
B Pump Installation Package,
(MSS 380 – HWW), complete with
double nipple, check valve, filter
short, washable filter cartridge, spi-
ral hose assembly 1 m, thread seal-
ing tape.
C Pump Installation Package,
(MSS 200 – HWW/P), complete
with double nipple, check valve, fil-
ter short, washable filter cartridge,
spiral hose assembly 1 m, thread
sealing tape.
D Pump Installation Package,
(MSS 1000 – HWA), complete with
double nipple, check valve, filter
short, washable filter cartridge, spi-
ral hose assembly 1 m, thread seal-
ing tape.
E Filter (for garden pumps),
1" connection, short,
c/w washable synthetic material fil-
ter cartridge.
F Filter (for domestic water systems),
1" connection, short,
c/w washable synthetic material fil-
ter cartridge.
G Spiral Suction Hose 1" (standard)
1) 4 m, c/w quick release screw fit-
ting and strainer with foot valve;
2) 7 m, c/w quick release screw fit-
ting and strainer with foot valve;
H Spiral Suction Hose 1" (profes-
sional)
1) 1.5 m, both ends with quick
release screw fitting;
2) 4 m, c/w quick release screw fit-
ting and strainer with foot valve;
3) 7 m, c/w quick release screw fit-
ting and strainer with foot valve;
I Reinforced Hose 500 mm
J Multi-adapter 1"
ideal for connecting to pumps with
1" AG connector
(AG=male thread, IG=female
thread)
K Hydrostop,
for automatic stopping when there
is a lack of water, prevents the
pump from running dry.
L Dry-running Stop Switch,
with 10 m cable, keeps the pump
from running dry when pumping
from tank, pool, etc.
M Thread Sealing Tape, 12 m roll.
N Washable Filter Cartridge, short,
for mechnical pre-filtering of sand,
reusable.
O Washable Filter Cartridge, long,
for mechnical pre-filtering of sand,
reusable.
8. Trouble Shooting
9. Repairs
10. Environmental Protection
11. Available Accessories










