12. Technische gegevens
Apparaat
150/20 XT 165 SP 170/30 XTC (combi) 200/40 XT 250/60 XT 300/45 XT
Netaansluitspanning
1~230V 1~230V 2~400V 1~230V 2~400V 3~400V
Netfrequentie
50-60 Hz
Vrijloopspanning
36 V 36,5V 38 V 34 V 35 V 34 V 35 V 39 V
Werkspanning
15,5..
.21,5 V
15,25...
21,25V
17,25...
22,25 V
15,5...
21,75V
17...
22,5 V
15,5...
24 V
15,5...
26,5 V
15,5...
29 V
Stroominstelbereik
1/2 1/2 1/2
Positie 1
30 A 25 A 65 A 30 A 60 A 30/100 A 30/100 A 30/125 A
Positie 2
50 A 45 A 85 A 45 A 90 A 50/120 A 40/120 A 50/150 A
Positie 3
75 A 70 A 110 A 80 A 120 A 65/140 A 60/160 A 75/190 A
Positie 4
100 A 95 A 125 A 110 A 140 A 75/160 A 75/190 A 95/230 A
Positie 5
130 A 120 A 150 A 140 A 160 A 95/185 A 90/225 A 115/280 A
Positie 6
150 A 145 A 165 A 155 A 170 A 110/200 A 110/250 A 140/300 A
Ingangsvermogen max.
5,8 KVA 5,6 KVA 6,8 KVA 5,8 KVA 6,7 KVA 7,0 KVA 8,9 KVA 12,1 KVA
Maximale ingangsstroom
Effectieve stroom
25 A
11,2 A
24,5 A
12,3 A
16,9 A
7,7 A
25 A
13,7 A
16,6 A
9,1 A
9,7 A
6,1 A
12,8 A
9,9 A
17,5 A
11,7 A
Max. inschakelduur (25°C)
100% inschakelduur bij
20%
50 A
25%
70 A
25%
65 A
30%
80 A
30%
90 A
40%
120 A
60%
190 A
45%
190 A
Max. inschakelduur (40°C)
100% inschakelduur bij
15%
50 A
17%
50 A
15%
45 A
20%
45 A
20%
60 A
30%
100 A
40%
160 A
30%
150 A
Lasniveau´s
6 niveau´s 6 Stufen
(230 V)
6 Stufen
(400 V)
6 niveau´s
(230 V)
6 niveau´s
(400 V)
2 x 6 niveau´s
Lasbare draad
0,6…0,8
mm
0,6…0,8
mm
0,6…0,8
mm
0,6…1,0
mm
0,6…1,2
mm
Beschermklasse
SK I
Beschermsoort
IP 23
Koelsoort
F
Isolatieklasse
F
Netzekering
T16A
Netstekker
Veilig-
heidsstop-
contact
16 A
Schuko
16 A
CEE
16 A
Veilig-
heidsstop-
contact
16 A
CEE
16 A
CEE
16 A
Afmetingen L x B x H (mm)
854 x 338 x 782 954 x 384 x 882
Gewicht (kg)
59,5 60,5 68,5 91 102 104