Operation Manual

10
ENGLISH
12. Technical Specifications
Model E 130* E 140 SP* E 140 SP Plus* E 150* E 170 Si
Supply voltage 230 V (-15% / -20%) / 50 – 60 Hz
Open-circuit voltage manual arc V 90 103 85 90 90
Open-circuit voltage TIG V 25 85 25 25
Working voltage manual arc V 20.4 – 25.2 20.4 – 25.6 20.4 – 26 20.4 – 26 20.4 – 26.8
Working voltage TIG V 10.4 – 15.2 10.4 – 15.6 10.4 – 16 10.4 – 16.8
Current setting range, stepless A 10 – 130 10 – 140 10 – 140 10 – 150 10 – 170
Power input max. kVA 6.0 6.6 6.6 7.1 5.7
Max. input current A 26 29 29 31 25
Max. duty cycle E 40 °C % 25 15 20 25 25
Max. duty cycle TIG 40 °C % 35 25 35 35
60% duty cycle E 40 °C: A 100 85 85 110 130
60% duty cycle TIG 40 °C A 115 100 130 140
100% duty cycle E 40 °C A 80 75 75 90 100
100% duty cycle TIG 40 °C A 100 85 110 110
Protection class IP23C IP23C IP23C IP23C IP23C
Max. electrode size Ø mm 3.25 3.25 3.25 3.25 (4.0 CrNi) 4.0
Cooling F F F F F
Supply circuit fuse T16A T16A T16A T16A T16A
Dimensions L x W x H (mm) mm 300x130x210 300x130x210 300x130x210 300x130x210 400x210x240
Weight (net) kg 6.2 5.8 6.0 6.3 7.8
* Warning: This device does not meet the requirements of EN/IEC 61000-3-12. Prior to connecting the device to a mains supply, the
owner or user of the device must ensure that the device can be connected, if necessary after consultation with the operator of the
mains supply network.