User Manual

ENGLISHen
14
6.1 Regular care
Regular care is required for the pump to func-
tion perfectly at all times. This also applies if
the pump is not switched on for extended pe-
riods of time (e.g. during operation in soaka-
ways).
Cleaning the pump
1. Rinse pump with clean water. Remove
persistent marks, e.g. algae deposits, with
brush and dishwashing liquid.
2. To rinse the inside of the pump:
dip pump into a container of clean water
and switch on briefly.
6.2 Pump storage
Caution!
Frost damages the pump and ac-
cessories as both always contain
water!
If there is a danger of frost, disassemble
pump and accessories and store in frost-
free conditions.
6.3 Device maintenance (only for
SP 28-50 S Inox, DP 28-10 S
Inox)
Caution!
Lubricant may leak from the pump if
the seals are defective, causing con-
tamination of the liquid being pumped.
Although the lubricant contained in the sub-
mersible pump for dirty water is non-toxic, it
can alter the water properties.
Danger!
Maintenance work must only ever
be carried out by qualified, special-
ly trained staff. After 4,000 to max. 8,000
hours of operation, and in any case at least
once a year, the quantity and quality of the oil
in the oil reservoir must be checked.
Danger!
Prior to all servicing:
Unplug.
7.1 Troubleshooting guide
Pump does not run:
No mains voltage.
Check cables, plug, outlet and mains
fuse.
Mains voltage too low.
Use an extension cable with sufficient
conductor diameter.
Motor overheated; motor protection relay
tripped.
Eliminate the cause of overheating
(pump blocked by foreign objects?).
Float switch does not switch pump ON
when water level rises.
Make sure the float switch can move
unrestrictedly. If, despite sufficient mo-
bility of the float switch, the pump does
not switch ON: send the pump to the
service centre in your country.
Motor hums, but does not start:
Pump blocked by foreign objects.
Clean impeller.
Pump runs, but does not pump properly:
Delivery head too high.
Observe max delivery head (see 'Tech-
nical Specifications').
Discharge hose kinked.
Straighten discharge hose.
Discharge hose leaky.
Seal discharge hose; tighten screw fit-
tings.
Pump runs very noisily:
Pump is sucking air.
Ensure there is a sufficient water sup-
ply.
Foreign objects are present (clean
pump).
Manual mode has been set (shallow
water suctioning).
Hold pump at an angle when submerg-
ing.
Pump runs continuously:
Float switch does not reach cut-out posi-
tion.
Make sure the float switch can move
freely.
Danger!
To avoid risks, only have repairs car-
ried out by qualified electricians using
original Metabo spare parts.
If you have Metabo electrical tools that re-
quire repairs, please contact your Metabo
service centre. For addresses see www.me-
tabo.com.
7. Troubleshooting
8. Repairs