User Manual
14
ENGLISH
• Pump blocked or out of order.
− see above.
• Hydromat incorrectly adjusted, fault
indicator lamp is on.
− Check cut-in pressure, readjust if
necessary.
8.2 Hydromat adjustment
When the cut-in pressure is too high and
the fault indicator lamp (11) is on, the
Hydromat needs to be readjusted.
1. Unplug.
2. Turn the regulating screw (12) as
follows:
− counter-clockwise to decrease
the cut-in pressure;
− clockwise to increase the cut-in
pressure.
3. Start equipment again and check
function (see "Operation").
A
Danger!
Repairs to electric tools must
only be carried out by a qualified
electrician!
Electric tools in need of repair can be
sent to an authorised service center in
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.
For shipping:
• Drain pump completely (see "Equip-
ment dismounting and storing").
• Dismount Hydromat (to prevent
shipping damage).
• Ship equipment in original packing,
if possible.
The packaging of the pump can be
100 % recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
For this equipment the following acces-
sories are available at specialist dealers.
3
Note:
Illustrations and stock numbers
can be found at the end of these instruc-
tions.
A Pump Installation Package,
complete with double nipple, check
valve, filter short, washable filter
cartridge, spiral hose assembly
1 m, thread sealing tape.
B Hydrostop,
for automatic stopping when there
is a lack of water, prevents the
pump from running dry.
C Dry-running Stop Switch,
with 10 m cable, keeps the pump
from running dry when pumping
from tank, pool, etc.
D Spiral Hose 1"
1) 1 m assembly, with quick
release screw fitting at both
ends;
2) 4 m, complete with quick
release screw fitting and
strainer with foot valve;
3) 7 m, complete with quick
release screw fitting and
strainer with foot valve.
E Filter, 1" connection, short,
complete with washable plastic fil-
ter cartridge.
F Disposable Filter Cartridge, short,
for mechanical preliminary filtering
of sand.
G Washable Filter cartridge, short,
for mechanical preliminary filtering
of sand, reusable.
H Activated Carbon Filter Cartridge,
short,
for use with chlorous water,
removes odours or discolouring.
I Filter Cartridge Poly, short,
filled with polyphosphate, for calcif-
erous water supplied to water heat-
ers.
J Pipe Nipple 150 mm, 1" male at
both ends, galvanized, to connect
pump and filter.
K Double Nipple, 1" male at boths
ends.
L Check Valve 1" female, prevents
water backflow and pump running
dry.
M Thread Sealing Tape, 12 m roll.
9. Repairs
10. Environmental Protection
11
12
11. Available Accessories