English
(6) Set the switching device to the downward
position (CONTACT ACTUATION
MECHANISM).
(Set the switching device to the downward
position completely as shown in the
diagram. Otherwise, it will not operate
properly.)
Switching Device
Downward position
With the Nailer off the workpiece, pull the
trigger.
Depress the push lever against the
workpiece.
□ The nailer must operate.
(7) If no abnormal operation is observed, you
may load nails in the Nailer.
Drive nails into the workpiece that is
the same type to be used in the actual
application.
□ The nailer must operate properly.
ADJUSTING AIR PRESSURE
WARNING
● Do not exceed 120 psi (8.3 bar 8.5
kgf/cm
2
).
Adjust the air pressure at recommended
operating pressure 70 – 120 psi (4.9 – 8.3
bar 5 – 8.5 kgf/cm
2
) according to the length
of nails and the hardness of workpiece.
The correct air pressure is the lowest
pressure which will do the job. Using the
Nailer at a higher than required air pressure
unnecessarily over stresses the Nailer.
LOADING NAILS
WARNING
● When loading nails into the nailer,
be sure to remove your fi nger from
the trigger and disconnect the air
hose from the nailer.
(1) Insert nail strip into rear of magazine.
Magazine
(2) Slide the nail strip forward in the magazine.
The nail strip should pass the nail stopper.
Nail Stopper
(3) Pull the nail feeder (B) back to engage the
nail feeder (A) to the nail strip.
Nail Feeder (B)
Nail Feeder (A)
NOTE
Use nail strip at least 5 nails remaining.